Infrared Thermography Case Histories - Steam Trap Monitoring

Applied Diagnostics Ltd - Precision with Pride

*

Recommendations

This steam trap is operating correctly, exhibiting a clear temperature drop between the condensate and live steam side. No action required, reassess in 6-12 months.



*

Recommendations

Negligible temperature drop is observed across the device, further more the temperature is above 100.0 Degrees Celsius indicating steam is passing into the condensate return line. Replacement of this trap is required.